2. EXTERNAL DIMENSIONS
YKB/YLM 2nd
MEE15K022
7
76
60
60XA=B
60XA=B
60
46
90
200
255
284
128
58
Connection pipe of
indoor unit(Liquid)
Connection pipe of
indoor unit(Gas)
27
X
Drain hose I.D.32 (1-1/4”)
Band(Accessory)
7
420
180
3
CMB-P104V
-GB1
CMB-P108V
-GB1
Access
door
450
250
(700)
200
(200)
362
181
298
(Lifting bolt pitch)
(Lifting bolt pitch)
B
A
Indoor unit model (Note 5.)
P50 or less:
Ø
6.35<Brazed>
P50 over
:
Ø
9.52<Brazed>
Indoor unit model (Note 5.)
P50 or less:
Ø
12.7<Brazed>
P50 over
:
Ø
15.88<Brazed>
248
Connection pipe of MAIN BC CONTROLLER                
(High pressure)
Connection pipe of MAIN BC CONTROLLER   
(Low pressure)
648
702
Drain pipe O.D.32 (1-1/4”)
12
14
30
Control box
103
169
45
130
130
23
130
70
Y
Ø
31
Connection pipe of MAIN BC CONTROLLER(Liquid)      
(Note 2.)
6
5
4
3
2
1
8
Detail of X section
Detail of
Y
 section
Service space
T
otal capacity of indoor units at SUB BC CONTROLLER
P200 or less:
Ø
19.05<Brazed>(use attachment pipe)
P300 or less:
Ø
22.2<Brazed>
P300 over:
Ø
28.6<Brazed>(use attachment pipe)
T
otal capacity of indoor units at SUB BC CONTROLLER
P200 or less:
Ø
15.88<Brazed>(use attachment pipe)
P200 over:
Ø
19.05<Brazed>
T
otal capacity of indoor units at SUB BC CONTROLLER
P300 or less:
Ø
9.52<Brazed>
P300 over:
Ø
12.7<Brazed>(use attachment pipe)
<Accessories>
Refrigerant<Low pressure> conn. pipe
············
4pcs.
Refrigerant<High pressure> conn. pipe
···········
2pcs.
Refrigerant<Liquid> conn. pipe
······················
2pcs.
Drain hose I.D.32 (1-1/4”)
·····························
1pc.
Hose band
·················································
1pc.
T
ie band
····················································
1pc.
Note1.Suspension bolt(
Ø
10),washer(M10),and nut(M10)
      prepare in the field.
    2.T
ake notice of service space as follows.
      (Please give attention not to occupy service
      space by letting ducts and pipes through.)  
    3.Can't use singleness.(MAIN BC CONTROLLER is necessary
.)
    4.Install this product in a location where noise (refrigerant noise)
      emitted by the unit will not disturb the neighbors.
    (For use in quiet enviroments with low background noise,position
     the BC CONTROLLER at least 5m away from any indoor units.)
    5.Refer to the Installation Manual for refrigerant piping diameter size
      when connecting plural indoor units with 1 branch.
Z
Detail of Z section
Cutting point
Cutting point
(Indoor unit Model:P50 or less)
(Indoor unit Model:P50 over)
CMB-P104, 108V-GB1
Unit : mm