1 - 236
BC
2. EXTERNAL DIMENSIONS
YKB/YLM 2nd
MEE15K022
70
Ø
31
(Note 2,3.)
200
260
250
(700)
200
200
289
128
74
27
Band(Accessory)
Drain hose I.D.32 (1-1/4”)
90
(200)
Access
door
450
450
CMB-P1010V
-GA1
CMB-P108V
-GA1
CMB-P1013V
-GA1
7
12
420
540
720
CMB-P1016V
-GA1
15
900
9
333
388
X
Y
(Lifting bolt pitch)
(Lifting bolt pitch)
A
B
Indoor unit model (Note 5.)
P50 or less:
Ø
6.35<Brazed>
P50 over
:
Ø
9.52<Brazed>
Indoor unit model (Note 5.)
P50 or less:
Ø
12.7<Brazed>
P50 over
:
Ø
15.88<Brazed>
Connection pipe of outdoor unit(High pressure)
Connection pipe of
indoor unit(Gas)
Connection pipe of
indoor unit(Liquid)
Connection pipe of
SUB BC CONTROLLER
(Low pressure)
Connection pipe of
SUB BC CONTROLLER
(Liquid)
Connection pipe of
SUB BC CONTROLLER
(High pressure)
14
12
30
268
Connection pipe of outdoor unit
(Low pressure)
111
0
1
164
210
128
268
Drain pipe O.D.32 (1-1/4”)
T
otal capacity of indoor unit
at SUB BC CONTROLLER
P300 or less :
Ø
9.52<Brazed>
P400 or less :
Ø
12.7<Brazed>
(use attachment pipe of
SUB BC CONTROLLER)
P400 over
:
Ø
15.88<Brazed>
(use attachment pipe of
JOINT<option>)
T
otal capacity of indoor unit
at SUB BC CONTROLLER
P200 or less:
Ø
19.05<Brazed>
(use attachment pipe of
SUB BC CONTROLLER)
P300 or less:
Ø
22.2<Brazed>
P300 over:
Ø
28.6<Brazed>
(use attachment pipe of
SUB BC CONTROLLER)
T
otal capacity of indoor unit
at SUB BC CONTROLLER
P200 or less:
Ø
15.88<Brazed>
(use attachment pipe of
SUB BC CONTROLLER)
P350 or less:
Ø
19.05<Brazed>
P350 over
:
Ø
22.2<Brazed>
(use attachment pipe of
JOINT<option>)
Control box
90
74
103
66
103
130
130
23
130
60XA=B
60
46
60XA=B
60
76
16
15
14
13
12
11
10
9
8
7
6
5
4
3
2
1
Detail of X section
Detail of
Y
section
Service
space
P250,300,350:
Ø
19.05<Brazed>(use attachment pipe)
P400,450,500:
Ø
22.2 <Brazed>
P550,600,650:
Ø
28.6 <Brazed>(use attachment pipe)
<Accessories>
Refrigerant<Low pressure> conn. pipe
····
1pc.
Refrigerant<High pressure> conn. pipe
···
2pcs.
Drain hose I.D.32 (1-1/4”)
·····················
1pc.
Hose band
·········································
1pc.
T
ie
band
············································
1pc.
Note1.Suspension bolt(
Ø
10),washer(M10),and nut(M10)
prepare in the field.
2.T
ake notice of service space as follows.
(Please give attention not to occupy service
space by letting ducts and pipes through.)
3.Please take service space for connection pipe of SUB BC CONTROLLER.
4.Install this product in a location where noise (refrigerant noise)
emitted by the unit will not disturb the neighbors.
(For use in quiet enviroments with low background noise,position
the BC CONTROLLER at least 5m away from any indoor units.)
5.Refer to the Installation Manual for refrigerant piping diameter size
when connecting plural indoor units with 1 branch.
P250,300:
Ø
22.2<Brazed>(use attachment pipe)
P350,400,450,500,550,600,650:
Ø
28.6<Brazed>
Z
Detail of Z section
Cutting point
Cutting point
(Indoor unit Model:P50 or less)
(Indoor unit Model:P50 over)
CMB-P108, 1010, 1013, 1016V-GA1
Unit : mm