1 .. 857 858 859 860 861 862 863 864 865 866 867 .. 908
4 - 79
2. M-NET control
YKB/YLM 2nd
S.D. R2
MEE15K022
2. M-NET control
2-1. Transmission cable length limitation
OC, OS: Outdoor unit controller; IC: Indoor unit controller; MA: MA remote controller
OC, OS: Outdoor unit controller; IC: Indoor unit controller; ME: ME remote controller
M2
TB7
TB3
IC
(52)
M1
  M2
1
2
S
TB5
TB15
1
2
TB15
1
2
TB15
1
2
TB15
1
2
TB15
1
2
TB 15
1
2
TB15
MA
(01)
IC
M1
  M2
S
TB5
(02)
IC
M1
  M2 S
TB5
(04)
IC
M1
  M2
S
TB5
(03)
IC
M1
  M2
S
TB5
(05)
IC
M1
  M2
S
TB5
(07)
IC
M1
  M2
S
TB5
(06)
L
2
L
1
L
8
MA
MA
MA
OS
TB7
(51)
OC
M1M2
S
TB7
TB3
(54 )
OC
a1
a4
a3
L
8
L
3
L
4
a2
A
B
A
B
A
B
A
B
BC(Sub)
M1
  M2 S
TB02
(55)
BC(Sub)
M1
  M2 S
TB02
(57)
a2
a1
a1
a2
Group1
Group3
Group5
L
2
M2
M1
M1
M2
M1
M2S
M2
M1
M1
S
TB3
IC
Group1
Group3
Group5
M1
  M2 S
TB5
ME
(01)
IC
M1
  M2 S
TB5
(02)
IC
M1
  M2 S
TB5
(04)
IC
M1
  M2 S
TB5
(03)
IC
M1
  M2
S
TB5
(05)
IC
M1
  M2
S
TB5
(07)
IC
M1
  M2 S
TB5
(06)
L
1
(101)
ME
(105)
ME
(103)
ME
(155)
e3
L
4
L
5
e2
e4
A
B
A
B
A
B
A
B
Shielded wire
  M2
BC(Main)
M1
  M2 S
TB02
(53)
BC(Main)
M1
S
TB02
(56)
Shielded wire
  M2
BC(Main)
M1
  M2
S
TB02
(53)
BC(Main)
M1
S
TB02
(56)
BC(Sub)
M1
  M2 S
TB02
(55)
BC(Sub)
M1
  M2 S
TB02
(57)
M2
TB7
TB3
(52)
OS
TB7
(51)
OC
M1M2S
TB7
TB3
(54 )
OC
L
3
M2
M1
M1
M2
M1
M2
S
M2
M1
M1
S
TB3
2-1-2. Using ME Remote controller
2-1-1. Using MA Remote controller
Long transmission cable causes voltage down, therefore, the length limitation should be obeyed to secure proper transmission.
Max. length via Outdoor (M-NET cable)
L1+L2+L3+L4, L1+L2+L6+L7, L3+L4+L6+L7
<=500m[1640ft.]
1.25mm
2
 [AWG16] or thicker
Max. length to Outdoor (M-NET cable)   L1+L8, L3+L4, L6, L2+L6+L8, L7
<=200m[656ft.]
1.25mm
2
 [AWG16] or thicker
Max. length from MA to Indoor
a1+a2, a1+a2+a3+a4
<=200m[656ft.]
0.3-1.25 mm
2
 [AWG22-16]
24VDC to AG-150A
n
<=50m[164ft.]
0.75-2.0 mm
2
 [AWG18-14]
Long transmission cable causes voltage down, therefore, the length limitation should be obeyed to secure proper transmission.
Max. length via Outdoor (M-NET cable)
 
L1+L2+L3+L4, L1+L2+L6+L7,L1+L2+L3+L5, L3+L4+L6+L7
<=500m[1640ft.] 1.25mm
2
 [AWG16] or thicker
Max. length to Outdoor (M-NET cable)
L1+L8, L3+L4, L6, L2+L6+L8, L7, L3+L5
<=200m[656ft.]
1.25mm
2
 [AWG16] or thicker
Max. length from ME to Indoor
e1, e2+e3, e4
<=10m[32ft.]*1
0.3-1.25 mm
2
[AWG22-16] *1
24VDC to AG-150A  
n
<=50m[164ft.]
0.75-2.0 mm
2
[AWG18-14]
 
*1. If the length from ME to Indoor exceed 10m, use 1.25 mm
2  
[AWG16] shielded cable, but the total length should be counted into Max. length via Outdoor.
AE-200E
L
6
S
A
B
AE-200E
L
6
S
A
B
V+V-FG
n
V+V-FG
S
Power Supply Unit
AG-150A
PAC-SC51KUA
L
6
L
7
A
B
S
A
B
V+V-FG
n
V+V-FG
S
Power Supply Unit
AG-150A
PAC-SC51KUA
L
6
L
7
A
B
S
A
B