1 .. 90 91 92 93 94 95 96 97 98 99 100 .. 908
1 - 90
PEFY-E-F
MEE15K022
1. SPECIFICATIONS
YKB/YLM 2nd
I.
Ceiling concealed (Fresh ai
r intake type)
1. SPECIFICATIONS
*1
*1
*1
*2
*3
*3
*3
*4
*4
*4
*4
Note :
Indoor :
Outdoor :
Pipe length :
Level difference :
33°CDB/28°CWB (91°FDB/82°FWB)
33°CDB (91°FDB)
7.5 m (24-9/16 ft)
0 m (0 ft)
-
-
-
-
Unit converter
0°CDB/-2.9°CDB (32°FDB/27°FDB)
0°CDB/-2.9°CDB (32°FDB/27°FDB)
7.5 m (24-9/16 ft)
0 m (0 ft)
* Due to continuing improvement, above specification may be subject to change without notice.
*4 The values are measured at the factory setting of external static pressure.
*5 The factory setting of external static pressure is shown without < >.
Refer to "Fan characteristics curves", according to the external static pressure,
in DATA BOOK for the usable range of air flow rate.
Model
Power source
Cooling capacity
(Nominal)
Temp. range of
Cooling
Heating capacity
(Nominal )
 
Temp. range of
Heating
External finish
External dimension H x W x D
Net weight
Heat exchanger
FAN
Sound pessure level
 (Low-Mid-High)/(Low-High)
 (measured in anechoic room)
Insulation material
Air filter
Protection device
Refrigerant control device
Connectable outdoor unit
Diameter of
refrigerant pipe
Field drain pipe size
Drawing
Standard
attachment
Remark
Power input
Current input
Power input
Current input
Type x Quantity
External
static
press.
Motor type
Motor output
Driving mechanism
Airflow rate
(Low-Mid-High)
Liquid
Gas
External
Wiring
Refrigerant cycle
Document
Accessory
Optional long life filter
Optional filter box
Drain pump
Installation
kW
kcal / h
BTU / h
kcal / h
kW
A
kW
kcal / h
BTU / h
kW
A
 
mm
in.
kg (lbs)
Pa
mmH
2
O
Pa
mmH
2
O
Pa
mmH
2
O
Pa
mmH
2
O
kW
m
3
 / min
L / s
cfm
dB <A>
dB <A>
dB <A>
 
mm (in.)
mm (in.)
 
mm (in.)
(R410A)
(R410A)
(208V)
(220V)
(230V)
(240V)
PEFY-P80VMH-E-F
1-phase 220-240V 50Hz, 1-phase 208-230V 60Hz
3-phase, 4-wire,  380-415V   50/60Hz
21°CDB/15.5°CWB ~ 43°CDB/35°CWB
70°FDB/60°FWB ~ 109°FDB/95°FWB
*Thermo-off (FAN-mode) automatically starts if the outdoor temperature is lower than 21°CDB (70°FDB).
-10°CDB ~ 20°CDB
14°FDB ~ 68°FDB
*Thermo-off (FAN-mode) automatically starts if the outdoor temperature is higher than 20°CDB (68°FDB).
Galvanized
Cross fin (Aluminum fin and copper tube)
Direct-driven by motor
EPS, Polyethylene foam
Optional long life filter (synthetic fiber unwoven cloth filter) and filter box are recommended. Field supplied filter is also possible.
Fuse
LEV
R410A CITY MULTI
 Installation Manual, Instruction Book
Insulation pipe for refrigerant pipe, washer, drain hose, tie band, pipe
9.0
7,700
30,700
-
0.16/0.21
0.67/0.91
8.5
7,300
29,000
0.16/0.21
0.67/0.91
380 x 1,000 x 900
15 x 39-3/8 x 35-7/16
50 (111)
Sirocco fan x 1
0.09 (220V, 115Pa)
9.0
150
318
27-38-43        
33-43-45        
        -        
ø9.52 (ø3/8) Flare
ø15.88 (ø5/8) Flare
PAC-KE88LAF
PAC-KE80TB-F
PAC-KE04DM-F
PEFY-P140VMH-E-F
16.0
13,800
54,600
-
0.29/0.33
1.24/1.48
15.1
13,000
51,500
0.29/0.33
1.24/1.48
380 x 1,200 x 900
15 x 47-2/8 x 35-7/16
67 (148)
Sirocco fan x 2
 
0.14 (220V, 115Pa)
18.0
300
636
28-38-43        
34-43-45        
        -        
ø9.52 (ø3/8) Flare
ø15.88 (ø5/8) Flare
PAC-KE89LAF
PAC-KE140TB-F
PAC-KE04DM-F
PEFY-P200VMH-E-F
22.4
19,300
76,400
-
0.34/0.42
0.58/0.74
21.2
18,200
72,300
0.34/0.42
0.58/0.74
470 x 1,250 x 1,120
18-9/16 x 49-1/4 x 44-1/8
100 (221)
Sirocco fan x 2
<140> -200
<14.3> -20.4
<150> -210
<15.3> -21.4
<160> -220
<16.3> -22.4
-
-
0.20 (415V, 220Pa)
28.0
467
989
39-42
40-43
40-44
ø9.52 (ø3/8) Brazed
ø19.05 (ø3/4) Brazed
PAC-KE85LAF
PAC-KE250TB-F
PAC-KE04DM-F
PEFY-P250VMH-E-F
28.0
24,100
95,500
-
0.39/0.50
0.68/0.86
26.5
22,800
90,400
0.39/0.50
0.68/0.86
470 x 1,250 x 1,120
18-9/16 x 49-1/4 x 44-1/8
100 (221)
Sirocco fan x 2
<110> -190
<11.2> -19.4
<120> -200
<12.2> -20.4
<130> -210
<13.3> -21.4
-
-
0.23 (415V, 210Pa)
35.0
583
1,236
40-44
40-45
41-46
ø9.52 (ø3/8) Brazed
ø22.2 (ø7/8) Brazed
PAC-KE85LAF
PAC-KE250TB-F
PAC-KE04DM-F
(208,220V)
(230,240V)
(208,220V)
(230,240V)
(380V)
(400V)
(415V)
(380V)
(400V)
(415V)
(380V)
(400V)
(415V)
(380V)
(400V)
(415V)
<35> -85- <170>
<3.6> -8.7- <17.3>
<40> -115- <190>
<4.1> -1
1.7- <19.4>
<50> -130- <210>
<5.1> -13.3- <21.4>
<80> -170- <220>
<8.2> -17.3- <22.4>
Single phase induction motor
3-phase induction motor
<35> -85- <170>
<3.6> -8.7- <17.3>
<50> -1
15- <190>
<5.1> -11.7- <19.4>
<60> -130- <220>
<6.1> -13.3- <22.4>
<100> -170- <240>
<10.2> -17.3- <24.5>
a. When the PEFY-P-VMH-E-F is connected with the outdoor unit, the maximum connectable total indoor unit capacity is as follows.
                                              Heat pump model                                                Cooling only model      
                      110% (100% in case of heating below -5°C(23°F)                                 110%
b. Only the thermo-sensor in the remote controller or an extra remote thermo-sensor can be chosen as the room temperature
    sensor.                   
c. No Auto mode or Dry mode is available.                    
d. The fan temporally stops in defrosting.                    
e. The air flow rate should be kept lower than 110% of value above. Please see "FAN Curve" for details.  
                  
f.
As PEFY-P-VMH-E-F cools the outdoor air directly, dewing at the air outlet grilles is possible, and should be considered.
g. Air filter must be installed in the air intake side, and should be easy to maintain.
Details on foundation work, duct work, insulation work, electrical wiring, power source switch, and other items shall be referred to
the Installation Manual.
IU-W27-5926
IU-W65-3961
-
IU-W27-7653
IU-W65-3999
-
kcal/h
= kW x 860
BTU/h
= kW x 3,412
cfm
=
m
3
/min x 35.31
lbs
= kg / 0.4536
*Above specification data is
subject to rounding variation.
O.D. 32mm (1-1/4)
*5
*4
*1 Nominal cooling condition
*2 Nominal cooling condition
*3 Nominal heating condition