7. Cooling [Wall mounted]
YKB/YLM 2nd
7-9. Cooling capacity with PURY-(E)P450-650Y(S)LM-A1
7-10. Cooling capacity with PURY-(E)P700-800YSLM-A1
7-11. Cooling capacity with PURY-(E)P850-900YSLM-A1
PKFY-P-VBM-E,VHM-E,VKM-E
CA: Capacity (kW), SHC: Sensible Heat Capacity (kW)
Model size (Rated kW)
Indoor air temp.
21.5°C D.B.
23°C D.
B.
25°C D.
B.
27°C D.
B.
28°C D.
B.
30°C D.B.
32°C D.B.
15°C W.
B.
16°C W.B.
18°C W.B.
19°C W.B.
20°C W.B.
22°C W.B.
24°C W.B.
CA
SHC
CA
SHC
CA
SHC
CA
SHC
CA
SHC
CA
SHC
CA
SHC
15 (1.7)
1.5
1.1
1.5
1.1
1.7
1.1
1.7
1.2
1.8
1.2
1.9
1.2
2.0
1.2
20 (2.2)
2.0
1.4
2.0
1.5
2.2
1.4
2.2
1.5
2.3
1.5
2.5
1.5
2.6
1.5
25 (2.8)
2.5
1.8
2.6
1.8
2.7
1.8
2.8
1.9
2.9
1.9
3.1
1.9
3.3
1.9
32 (3.6)
3.2
2.5
3.3
2.6
3.5
2.6
3.6
2.7
3.8
2.7
4.0
2.7
4.3
2.7
40 (4.5)
4.0
3.1
4.1
3.1
4.4
3.1
4.5
3.3
4.7
3.3
5.0
3.3
5.4
3.3
50 (5.6)
5.0
3.6
5.1
3.7
5.5
3.7
5.6
3.9
5.9
3.9
6.3
3.8
6.7
3.8
63 (7.1)
6.3
5.0
6.5
5.1
6.9
5.1
7.1
5.4
7.4
5.4
7.9
5.4
8.5
5.3
100 (11.2)
10.0
7.3
10.2
7.5
11.0
7.4
11.2
7.8
11.7
7.9
12.5
7.8
13.4
7.7
* The capacity does not depend on the outdoor temperature.
kcal/h = kW x 860, BTU/h = kW x 3,412
PKFY-P-VBM-E,VHM-E,VKM-E
CA: Capacity (kW), SHC: Sensible Heat Capacity (kW)
Model size (Rated kW)
Indoor air temp.
21.5°C D.B.
23°C D.
B.
25°C D.
B.
27°C D.
B.
28°C D.
B.
30°C D.B.
32°C D.B.
15°C W.
B.
16°C W.B.
18°C W.B.
19°C W.B.
20°C W.B.
22°C W.B.
24°C W.B.
CA
SHC
CA
SHC
CA
SHC
CA
SHC
CA
SHC
CA
SHC
CA
SHC
15 (1.7)
1.5
1.1
1.5
1.1
1.6
1.1
1.7
1.2
1.8
1.2
1.9
1.2
2.0
1.2
20 (2.2)
1.9
1.4
2.0
1.4
2.1
1.4
2.2
1.5
2.3
1.5
2.4
1.5
2.6
1.5
25 (2.8)
2.5
1.8
2.5
1.8
2.7
1.8
2.8
1.9
2.9
1.9
3.1
1.9
3.3
1.9
32 (3.6)
3.2
2.5
3.3
2.6
3.5
2.6
3.6
2.7
3.7
2.7
4.0
2.7
4.2
2.7
40 (4.5)
3.9
3.0
4.1
3.1
4.4
3.1
4.5
3.3
4.7
3.3
5.0
3.3
5.3
3.2
50 (5.6)
4.9
3.6
5.1
3.7
5.4
3.7
5.6
3.9
5.8
3.9
6.2
3.8
6.6
3.8
63 (7.1)
6.2
4.9
6.4
5.1
6.9
5.1
7.1
5.4
7.4
5.4
7.9
5.4
8.3
5.3
1
0
0
(
1
1
.
2
)
9
.
8
7
.
2
1
0
.
1
7
.
4
1
0
.
9
7
.
4
1
1
.
2
7
.
8
1
1
.
6
7
.
8
1
2
.
4
7
.
7
1
3
.
2
7
.
6
* The capacity does not depend on the outdoor temperature.
kcal/h = kW x 860, BTU/h = kW x 3,412
PKFY-P-VBM-E,VHM-E,VKM-E
CA: Capacity (kW), SHC: Sensible Heat Capacity (kW)
Model size (Rated kW)
Indoor air temp.
21.5°C D.B.
23°C D.
B.
25°C D.
B.
27°C D.
B.
28°C D.
B.
30°C D.B.
32°C D.B.
15°C W.
B.
16°C W.B.
18°C W.B.
19°C W.B.
20°C W.B.
22°C W.B.
24°C W.B.
CA
SHC
CA
SHC
CA
SHC
CA
SHC
CA
SHC
CA
SHC
CA
SHC
15 (1.7)
1.5
1.1
1.5
1.1
1.7
1.1
1.7
1.2
1.8
1.2
1.9
1.2
2.0
1.2
20 (2.2)
2.0
1.4
2.0
1.5
2.2
1.4
2.2
1.5
2.3
1.5
2.5
1.5
2.6
1.5
25 (2.8)
2.5
1.8
2.6
1.8
2.7
1.8
2.8
1.9
2.9
1.9
3.1
1.9
3.3
1.9
32 (3.6)
3.2
2.5
3.3
2.6
3.5
2.6
3.6
2.7
3.8
2.7
4.0
2.7
4.3
2.7
40 (4.5)
4.0
3.1
4.1
3.1
4.4
3.1
4.5
3.3
4.7
3.3
5.0
3.3
5.4
3.3
50 (5.6)
5.0
3.6
5.1
3.7
5.5
3.7
5.6
3.9
5.9
3.9
6.3
3.8
6.7
3.8
63 (7.1)
6.3
5.0
6.5
5.1
6.9
5.1
7.1
5.4
7.4
5.4
7.9
5.4
8.5
5.3
100 (11.2)
10.0
7.3
10.2
7.5
11.0
7.4
11.2
7.8
11.7
7.9
12.5
7.8
13.4
7.7
* The capacity does not depend on the outdoor temperature.
kcal/h = kW x 860, BTU/h = kW x 3,412