1 .. 212 213 214 215 216 217 218 219 220 221 222 .. 908
1 - 212
LOSSNAY
3. SPECIFICATIONS
YKB/YLM 2nd
MEE15K022
LGH-100RVX-E
Heat recovery mode
Bypass mode
SP4
2.50
420
1000
278
170
80.0
72.5
71.0
37.0
SP3
1.20
200
750
208
96
83.0
74.0
73.0
31.0
SP2
0.50
75
500
139
43
86.5
78.0
77.0
23.0
SP1
0.17
21
250
69
11
89.5
87.0
85.5
18.0
SP4
2.50
420
1000
278
170
-
-
-
38.0
SP3
1.20
200
750
208
96
-
-
-
32.0
SP2
0.51
75
500
139
43
-
-
-
24.0
SP1
0.19
23
250
69
11
-
-
-
18.0
54
220-240V/50Hz, 220V/60Hz
*The Air outlets noise (45˚ angle,1.5meters in front of the unit) is about 21dB greater than the indicated value.(at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit between static pressure 60Pa and 240Pa at Fan speed4. Otherwise the motor protection may work and reduce its output or the noise level might be larger.
LGH-100RVX-E
Model
Electrical power supply
Ventilation mode
Fan speed
Running current (A)
Input power (W)
Air volume
(m
3
/h)
(L/s)
External static pressure (Pa)
Temperature exchange efficiency (%)
Enthalpy exchange efficiency (%)
 
Heating
Cooling
Noise (dB)
Weight (kg)
(Measured at 1.5m under the center
 of unit in an anechoeic chamber)
LGH-150RVX-E
Heat recovery mode
Bypass mode
SP4
3.71
670
1500
417
175
80.0
72.0
70.5
39.0
SP3
1.75
311
1125
313
98
82.5
73.5
72.5
32.0
SP2
0.70
123
750
208
44
84.0
78.0
78.0
24.0
SP1
0.29
38
375
104
11
85.0
81.0
81.0
18.0
SP4
3.85
698
1500
417
175
-
-
-
40.5
SP3
1.78
311
1125
313
98
-
-
-
33.0
SP2
0.78
124
750
208
44
-
-
-
26.0
SP1
0.30
44
375
104
11
-
-
-
18.0
98
220-240V/50Hz, 220V/60Hz
*The Air outlets noise (45˚ angle,1.5meters in front of the unit) is about 22dB greater than the indicated value.(at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit with static pressure 250Pa or less at Fan speed4. Otherwise the noise level might be larger.
LGH-150RVX-E
Model
Electrical power supply
Ventilation mode
Fan speed
Running current (A)
Input power (W)
Air volume
(m
3
/h)
(L/s)
External static pressure (Pa)
Temperature exchange efficiency (%)
Enthalpy exchange efficiency (%)
 
Heating
Cooling
Noise (dB)
Weight (kg)
(Measured at 1.5m under the center
 of unit in an anechoeic chamber)
LGH-200RVX-E
Heat recovery mode
Bypass mode
SP4
4.88
850
2000
556
150
80.0
72.5
71.0
40.0
SP3
2.20
400
1500
417
84
83.0
74.0
73.0
36.0
SP2
0.88
153
1000
278
38
86.5
78.0
77.0
28.0
SP1
0.33
42
500
139
10
89.5
87.0
85.5
18.0
SP4
4.54
853
2000
556
150
-
-
-
41.0
SP3
2.06
372
1500
417
84
-
-
-
36.0
SP2
0.87
150
1000
278
38
-
-
-
27.0
SP1
0.35
49
500
139
10
-
-
-
19.0
110
220-240V/50Hz, 220V/60Hz
*The Air outlets noise (45˚ angle,1.5meters in front of the unit) is about 21dB greater than the indicated value.(at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
*Use this unit between static pressure 50Pa and 220Pa at Fan speed4. Otherwise the motor protection may work and reduce its output or the noise level might be larger.
LGH-200RVX-E
Model
Electrical power supply
Ventilation mode
Fan speed
Running current (A)
Input power (W)
Air volume
(m
3
/h)
(L/s)
External static pressure (Pa)
Temperature exchange efficiency (%)
Enthalpy exchange efficiency (%)
 
Heating
Cooling
Noise (dB)
Weight (kg)
(Measured at 1.5m under the center
 of unit in an anechoeic chamber)