1 .. 210 211 212 213 214 215 216 217 218 219 220 .. 908
1 - 210
LOSSNAY
3. SPECIFICATIONS
YKB/YLM 2nd
MEE15K022
3.
 
S
P
E
C
IF
IC
A
T
IO
N
S
LGH-15RVX-E
Heat recovery mode
Bypass mode
SP4
0.40
49
150
42
95
80.0
73.0
71.0
28.0
SP3
0.24
28
11
3
31
54
81.0
75.5
74.5
24.0
SP2
0.15
14
75
21
24
83.0
78.0
78.0
19.0
SP1
0.10
7
38
10
6
84.0
79.0
79.0
17.0
SP4
0.41
52
150
42
95
-
-
-
29.0
SP3
0.25
28
113
31
54
-
-
-
24.0
SP2
0.15
14
75
21
24
-
-
-
19.0
SP1
0.10
8
38
10
6
-
-
-
18.0
20
220-240V/50Hz, 220V/60Hz
*The Air outlets noise (45˚ angle,1.5meters in front of the unit) is about 13dB greater than the indicated value.(at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
LGH-15RVX-E
Model
Electrical power supply
Ventilation mode
Fan speed
Running current (A)
Input power (W)
Air volume
(m
3
/h)
(L/s)
External static pressure (Pa)
Temperature exchange efficiency (%)
Enthalpy exchange efficiency (%)
 
Heating
Cooling
Noise (dB)
Weight (kg)
(Measured at 1.5m under the center
 of unit in an anechoeic chamber)
LGH-25RVX-E
Heat recovery mode
Bypass mode
SP4
0.48
62
250
69
85
79.0
69.5
68.0
27.0
SP3
0.28
33
188
52
48
80.0
72.0
70.0
22.0
SP2
0.16
16
125
35
21
82.0
76.0
74.5
20.0
SP1
0.10
7.5
63
17
5
86.0
83.0
83.0
17.0
SP4
0.48
63
250
69
85
-
-
-
27.5
SP3
0.29
35
188
52
48
-
-
-
23.0
SP2
0.16
17
125
35
21
-
-
-
20.0
SP1
0.11
9
63
17
5
-
-
-
17.0
23
220-240V/50Hz, 220V/60Hz
*The Air outlets noise (45˚ angle,1.5meters in front of the unit) is about 15dB greater than the indicated value.(at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
LGH-25RVX-E
Model
Electrical power supply
Ventilation mode
Fan speed
Running current (A)
Input power (W)
Air volume
(m
3
/h)
(L/s)
External static pressure (Pa)
Temperature exchange efficiency (%)
Enthalpy exchange efficiency (%)
 
Heating
Cooling
Noise (dB)
Weight (kg)
(Measured at 1.5m under the center
 of unit in an anechoeic chamber)
LGH-35RVX-E
Heat recovery mode
Bypass mode
SP4
0.98
140
350
97
160
80.0
71.5
71.0
32.0
SP3
0.54
70
263
73
90
82.5
74.0
73.0
28.0
SP2
0.26
31
175
49
40
86.0
78.5
78.0
20.0
SP1
0.12
11
88
24
10
88.5
83.5
82.0
17.0
SP4
0.98
145
350
97
160
-
-
-
32.5
SP3
0.56
72
263
73
90
-
-
-
28.0
SP2
0.28
35
175
49
40
-
-
-
20.0
SP1
0.13
13
88
24
10
-
-
-
18.0
30
220-240V/50Hz, 220V/60Hz
*The Air outlets noise (45˚ angle,1.5meters in front of the unit) is about 12dB greater than the indicated value.(at Fan speed 4)
*The running current, the input power, the efficiency and the noise are based on the rating air volume, and 230V/50Hz.
*For the specification at the other frequency contact your dealer.
LGH-35RVX-E
Model
Electrical power supply
Ventilation mode
Fan speed
Running current (A)
Input power (W)
Air volume
(m
3
/h)
(L/s)
External static pressure (Pa)
Temperature exchange efficiency (%)
Enthalpy exchange efficiency (%)
 
Heating
Cooling
Noise (dB)
Weight (kg)
(Measured at 1.5m under the center
 of unit in an anechoeic chamber)