1 .. 400 401 402 403 404 405 406 407 408 409 410 .. 908
2 - 100
Y
MEE15K022
8. CAPACITY TABLES
YKB/YLM 2nd
Total capacity of indoor units
Ratio of capacity
Ratio of power input
Total capacity of indoor units
Ratio of capacity
Ratio of power input
PUHY-P1250YSKB-A1
PUHY-P1300YSKB-A1
Cooling
Heating
600
800
1200
1600
1000
1400
1800
0.2
1.2
1.0
0.8
0.6
0.4
1.0
0.8
0.6
0.4
0.2
1.2
Cooling
Heating
600
800
1200
1600
1000
1400
1800
0.2
1.2
1.0
0.8
0.6
0.4
1.0
0.8
0.6
0.4
0.2
1.2
Nominal
Cooling
Capacity
Input
kW
BTU/h
kW
PUHY-P1250YSKB-A1
140.0
477,700
43.80
Nominal
Heating
Capacity
Input
kW
BTU/h
kW
PUHY-P1250YSKB-A1
156.5
534,000
44.08
Nominal
Cooling
Capacity
Input
kW
BTU/h
kW
PUHY-P1300YSKB-A1
146.0
498,200
47.80
Nominal
Heating
Capacity
Input
kW
BTU/h
kW
PUHY-P1300YSKB-A1
163.0
556,200
46.04